23x.36 6" High Ovpress Safety Gauge

The Wika 23x.36 High Overpressure Safety Gauge is engineered for handling occasional short-duration overpressure loads, making it ideal for applications involving gaseous and liquid aggressive media that are not highly viscous or crystallising. This gauge is a perfect fit for challenging environments found in the oil and gas industry, chemical and petrochemical sectors, power plants, mining operations, both onshore and offshore facilities, environmental technology, machine building, and general plant construction.


One of the standout features of the Wika 23x.36 gauge is its complete overpressure range indication, which ensures precision and reliability. It is designed with a solid baffle wall (Solidfront) for enhanced safety, adhering to the stringent requirements of EN 837-1 and ASME B40.100 standards. Additionally, the model 233.36 variant comes with case filling, making it suitable for applications subjected to high dynamic pressure loads and vibrations.


The gauge offers a wide range of measuring capacities, from 0 to 0.6 bar up to 0 to 40 bar (or 0 to 10 psi up to 0 to 600 psi), catering to diverse industrial needs. For those in need of a reliable, high-quality overpressure safety gauge, the Wika 23x.36 stands out for its durability and performance. Branom is the premier destination to purchase this exceptional gauge, ensuring you receive the best in both product quality and customer service.

693.54 693.54 USD 733.90

639.25

Not Available For Sale

  • Nominal Size
  • Case Filling
  • Scale Range
  • 2nd Scale
  • Process Connection
  • Connector Location
  • Mounting Flange / Bracket
  • Window
  • Restrictor
  • Pointer
  • Set / Drag Pointer
  • Special Design Features
  • Explosion Protection
  • Ignition Protection
  • Zone
  • Certificates
  • Approvals
  • Assembly Accessory
  • Additional Ordering Info
  • Accuracy Class
  • Case Material
  • Case Surface
  • Case Filling
  • Ingress Protection
  • Thread Protection
  • Origin of Wetted Parts
  • Pressure Gauge Standard
  • Color for Inner Scale
  • Logo Options
  • Manufacturer Logo
  • Serial Number
  • Stop Pin on Dial
  • Red Mark at
  • Text for Dial
  • *Gauge Brand
  • *Model
  • *Model
  • *Dial Size
  • *Scale Range
  • *Pressure Type
  • *Measuring Principle
  • *Fill Type
  • *Fill Type
  • *Product Unit of Measure
  • *Product Unit of Measure
  • *Product Unit of Measure
  • *Product Unit of Measure
  • *Product Unit of Measure
  • *Process Connection Size
  • *Process Connection Size
  • *Process Connection Location
  • *Wetted Material
  • *Accuracy
  • *Case Material
  • *Window
  • *Window
  • *Dial Material
  • *Pointer Material
  • *Bezel Material
  • *Window Ring
  • *Pointer Type

This combination does not exist.


Product Datasheets

Datasheet 1

Specifications

Wika 23x.36F
Case Filling [233.36-F] With or [232.36-F] Without
Scale Range ■ psi ■ or [PH269] 0/10 psi Overpressure Safe to 35 psi or [PH310] 0/15 psi Overpressure Safe to 60 psi or [PH341] 0/60 psi Overpressure Safe to 230 psi or [PH410] 0/150 psi Overpressure Safe to 580 psi or [PH417] 0/250 psi Overpressure Safe to 930 psi or [PH428] 0/400 psi Overpressure Safe to 1280 psi or [PH441] 0/600 psi Overpressure Safe to 1500 psi or ■ psi / -inHg ■ or [PQ310] -30 inHg/0 psi Overpressure Safe to 45 psi or ■ bar ■ or [BH260] 0/0.6 bar Overpressure Safe to 2.5 bar or [BH310] 0/1 bar Overpressure Safe to 4 bar or [BH316] 0/1.6 bar Overpressure Safe to 6 bar or [BH325] 0/2.5 bar Overpressure Safe to 10 bar or [BH340] 0/4 bar Overpressure Safe to 16 bar or [BH360] 0/6 bar Overpressure Safe to 25 bar or [BH410] 0/10 bar Overpressure Safe to 40 bar or [BH416] 0/16 bar Overpressure Safe to 60 bar or [BH425] 0/25 bar Overpressure Safe to 80 bar or [BH440] 0/40 bar Overpressure Safe to 100 bar or ■ bar vacuum ■ or [BQ310] -1/0 bar Overpressure Safe to 3 bar or [BQ316] -1/0.6 bar Overpressure Safe to 3 bar or [BQ325] -1/1.5 bar Overpressure Safe to 6 bar or [BQ340] -1/3 bar Overpressure Safe to 16 bar or [BQ360] -1/5 bar Overpressure Safe to 25 bar or [BQ410] -1/9 bar Overpressure Safe to 40 bar or [BQ416] -1/15 bar Overpressure Safe to 60 bar or [BQ425] -1/24 bar Overpressure Safe to 80 bar or ■ kPa ■ or [LH260] 0/60 kPa Overpressure Safe to 250 kPa or [LH310] 0/100 kPa Overpressure Safe to 400 kPa or [LH316] 0/160 kPa Overpressure Safe to 600 kPa or [LH325] 0/250 kPa Overpressure Safe to 1000 kPa or [LH340] 0/400 kPa Overpressure Safe to 1600 kPa or [LH360] 0/600 kPa Overpressure Safe to 2500 kPa or [LH410] 0/1000 kPa Overpressure Safe to 4000 kPa or [LH416] 0/1600 kPa Overpressure Safe to 6000 kPa or [LH425] 0/2500 kPa Overpressure Safe to 8000 kPa or [LH440] 0/4000 kPa Overpressure Safe to 10000 kPa or ■ kPa vacuum ■ or [LQ310] -100/0 kPa Overpressure Safe to 300 kPa or [LQ316] -100/60 kPa Overpressure Safe to 300 kPa or [LQ325] -100/150 kPa Overpressure Safe to 600 kPa or [LQ340] -100/300 kPa Overpressure Safe to 1500 kPa or [LQ350] -100/400 kPa Overpressure Safe to 2400 kPa or [LQ410] -100/900 kPa Overpressure Safe to 4000 kPa or [LQ416] -100/1500 kPa Overpressure Safe to 6000 kPa or [LQ425] -100/2400 kPa Overpressure Safe to 8000 kPa or ■ MPa ■ or [EH260] 0/0.06 MPa Overpressure Safe to 0.25 MPA or [EH310] 0/0.1 MPa Overpressure Safe to 0.4 MPA or [EH316] 0/0.16 MPa Overpressure Safe to 0.6 MPA or [EH325] 0/0.25 MPa Overpressure Safe to 1 MPA or [EH340] 0/0.4 MPa Overpressure Safe to 1.6 MPA or [EH360] 0/0.6 MPa Overpressure Safe to 2.5 MPA or [EH410] 0/1 MPa Overpressure Safe to 4 MPA or [EH416] 0/1.6 MPa Overpressure Safe to 6 MPA or [EH425] 0/2.5 MPa Overpressure Safe to 8 MPA or [EH440] 0/4 MPa Overpressure Safe to 10 MPA or ■ MPa vacuum ■ or [EQ310] -0.1/0 MPa Overpressure Safe to 0.3 MPA or [EQ316] -0.1/0.06 MPa Overpressure Safe to 0.3 MPA or [EQ325] -0.1/0.15 MPa Overpressure Safe to 0.6 MPA or [EQ340] -0.1/0.3 MPa Overpressure Safe to 1.5 MPA or [EQ360] -0.1/0.5 MPa Overpressure Safe to 2.4 MPA or [EQ410] -0.1/0.9 MPa Overpressure Safe to 4 MPA or [EQ416] -0.1/1.5 MPa Overpressure Safe to 6 MPA or [EQ425] -0.1/2.4 MPa Overpressure Safe to 8 MPA
2nd Scale [Z] Without or [B] bar or [P] psi or [L] kPa or [E] MPa or [K] kg/cm2
Process Connection [GD] G 1/2 B or [ND] 1/2 NPT
Mounting Flange / Bracket [Z] Without or [S] SS Surface Mounting Lugs or [M] Front Flange, Stainless Steel or [F] Front Flange, Polished SS (Standard)
Window [H] Laminated Safety Glass or [E] Polycarbonate
Restrictor [Z] Without or [Q] Stainless Steel, D 0.6
Pointer [C] Standard Pointer or [A] Adjustable Pointer
Set / Drag Pointer [ZZ-ZZZZZZZ2] Without or [AZ-ZZZZZZZ2] Red Mark Pointer on Dial or [RZ-ZZZZZZZ2] Externally Adjustable Red Set Pointer on Window or [SZ-ZZZZZZZ2] Externally Adjustable Red Drag Pointer on Window
Case Material [3] Stainless Steel 1.4301 (Standard) or [E] Stainless Steel 316Ti
Case Surface [D] Bare or [5] Epoxy Coated
Case Filling [Z] Without or [A] Glycerine or [G] Glycerine-Water-Mixture or [D] Silicon Oil, 50 Cst or [J] Glycerine for Food Applications or [R] Voltalef or [E] Silicon Oil M100 or [5] Glycerine for Oxygen Applications
Ingress Protection [I] IP 65 or [K] IP 66 or [L] IP 67
Thread Protection [ZZ-U] Without or [1Z-U] With thread protection
Color for Inner Scale [ZZZZZZ22] Without or [CZZZZZ22] Red or [AZZZZZ22] Black or [KZZZZZ22] Cooling Scale
Stop Pin on Dial [ZZZ] Without or [2ZZ] At 6 o'clock or [1ZZ] At Zero
Nominal Size 6"
Connector Location [U] Lower Mount
Special Design Features [Z] Without
Explosion Protection [Z] Without
Ignition Protection [Z] Without
Zone [Z] Without
Certificates [Z] Without
Approvals [Z] Without
Assembly Accessory [Z] Without
Additional Ordering Info [Z2] Without
Accuracy Class [L] +/- 1% (ASME B40.100 Grade 1A)
Origin of Wetted Parts [Z] Without Specification
Pressure Gauge Standard [U] US-Standard
Logo Options [ZZZZZ] Without
Manufacturer Logo [2] *WIKA®*
Serial Number [2] With Serial Number
Red Mark at [Z] Without
Text for Dial [Z] Without
Gauge Features
*Gauge Brand Wika
*Model 233.36, 232.36
*Dial Size 6 in (160 mm)
*Scale Range ≥ 10 psi (0.6 bar) to ≤ 15,000 psi (1,000 bar)
*Pressure Type Gauge Pressure
*Measuring Principle Bourdon Tube
*Fill Type Dry, Liquid Filled / Fillable
*Product Unit of Measure psi / inHg, bar, kPa, MPa, kg/cm2
*Process Connection Size 1/2 NPT, G 1/2 B
*Process Connection Location Lower Mount
*Wetted Material Stainless Steel
*Accuracy ±1%
*Case Material Stainless Steel
*Window Polycarbonate, Laminated Safety Glass
*Dial Material Aluminum, White
*Pointer Material Aluminum, Black
*Bezel Material None
*Window Ring Bayonet Ring
*Pointer Type Adjustable